产 品 说 明
ASE光源模块 L型ASE光源模块
Symbol | Function | Wire-I# | Symbol | Function | |
1 | GND1 | Ground1 | 11 | NC | |
2 | +5V1 | Power Supply1 | 12 | LDSD | LD Shutdown |
3 | GND1 | Ground1 | 13 | NC | |
4 | +5V1 | Power Supply1 | 14 | NC | |
5 | TEMP-MON | Temperature Monitor | 15 | TXD | CPU Transmit Data |
6 | GBO-MON | Gain-Black Output Monitor | 16 | RXD | CPU Receive Data |
7 | LDR-MON | LD Power Monitor | 17 | +5V2 | Power Supply2 |
8 | LDC-MON | LD Current Monitor | 18 | GND2 | Ground2 |
9 | LDC-ALM | LD Current Alarm | 19 | +5V2 | Power Supply2 |
10 | GBO-ALM | Gain-Block Qutput Alam | 20 | GND2 | Ground2 |
■Electrical specification
Monitor function | ASE power | |
Pumping LD current | ||
Pumping LD temperature | ||
Pumping LD power | ||
Alarm function | 3dB ASE power degradation gives alarm | |
20% rise of pumping LD current gives alarm | ||
Control function | LD shutdown function | Pumping LD is shut down gy a short with Ground Pin |
LD restart function | Pumping LD restars by removing a short with Ground pin | |
Others | Operation | |
Storage temperature | -20~70oC | |
Power supply | DC5V |