New! USB communication enabled Model 843-USB
Compact handheld design with rubber bumpers and a kickstand
Clear TFT 320 X 240 display
Digital value display with either bar graph or a simulated analog needle
Analog output
Single shot energy measurement with a thermopile sensor
Compatible with photodiode detectors and new 919P series thermopile sensors
Backlighting and rechargeable battery
Sampling Rate | 15 Hz |
Display Refresh Rate | 15 Hz |
Display Type | High legibility TFT 320 x 240 pixel graphics LCD |
Display | 15 mm numeric display. High resolution analog needle also can be chosen. |
Compatible Detectors | 详询销售工程师 |
Detector Type | Low Power, High Power, Energy |
Detector Input | Up to 1.3 mA for Photodiode Sensors |
Accuracy![]() | ±0.25 % (Full Scale) ± 20 p A |
Maximum Detector Input Current | 1.4 mA |
Maximum Input Power | Detector dependent |
Resolution | 18 bits plus sign |
Wavelength Range | Detector dependent |
Analog Output | 0-1 V into 100 Ω, mono audio 2.5 mm jack (included) |
Communication Interfaces | None |
Data Storage | None |
Battery Life | 14 hours typical between charges. |
Battery | Rechargeable Li-ion Batteries |
Power Requirements | DC 12 - 16 V, 1W |
Length | 40 mm ( 1.6 in.) |
Height | 8.4 in. ( 213 mm) |
Width | 4.4 in. ( 113 mm) |
Weight | 1.0 lb ( 0.47 kg) |
RoHS | Compliant |
CE Certified | Yes
常用配置参数 Wavelength Range190 to 10,60nmPower Range1 mW - 10 WPulse Energy, Maximum - w/o Attenuator1 nJ/cm2Calibration Uncertainty3 %Calibration Uncertainty, w/ AttenuatorN/A |
选配探头:
Model 红外探头1
Spectral Range 780 to 1800 nm
Max. Measurable Power 2 W
Max. Measurable Power w/o Attenuator 10 mW
Pulse Energy Density, Maximum - w/o Attenuator 5 µJ/cm2
Active Diameter 0.3 cm
Detector Active Area 0.071 cm2
Power Density, Maximum Average 30 W/cm2
Pulse Energy, Maximum - w/ Attenuator 5 u J
Pulse Energy, Maximum - w/o Attenuator 5 n J
Material Germanium
Uniformity ±2 %
Calibration Uncertainty 2% @ 780-910nm, 2% @ 911-1700nm, 4%@1701-1800 nm
Calibration Uncertainty, w/ Attenuator 5% @ 780-910nm, 2% @ 911-1700nm, 4% @ 1701-1800 nm
Minimum Detectable Power 5 n W
Pulse Energy Density, Maximum - w/ Attenuator 5 mJ/cm2
Linearity ±0.5 %
Model 红外探头2
Spectral Range 780 to 1800 nm
Max. Measurable Power 2 W
Max. Measurable Power w/o Attenuator 5 mW
Pulse Energy Density, Maximum - w/o Attenuator 5 nJ/cm2
Connector Type DB15 - Newport Compatible
Active Diameter square 1 x 1 cm
Detector Active Area 1 cm2
Power Density, Maximum Average 30 W/cm2
Pulse Energy, Maximum - w/ Attenuator 0.35 u J/cm2
Pulse Energy, Maximum - w/o Attenuator 0.35 nJ/cm2
Material Germanium
Uniformity ±2 %
Calibration Uncertainty 2% @ 780-910nm, 2% @ 911-1700nm
4%@1701-1800 nm
Calibration Uncertainty, w/ Attenuator 5% @ 780-910nm, 2% @ 911-1700nm
4% @ 1701-1800 nm
Pulse Energy Density, Maximum - w/ Attenuator 5 µJ/cm2
Linearity ±0.5 %
更多探头选配,请详询销售工程师 400-050-3150