High intensity UV sources, ideal for DUV-VIS fluorescence spectroscopy
Produce collimated or focused output
Complete systems include lamp, lamp housing with condensor lens, and power supply
Simple, safe setup and operation
Each light source part number begins with its Legacy Part Number, the predecessor to these light sources. The rest of the part number tells the lamp power and type of lamp included, along with the type of lamp housing and F/# of the condensor lens assembly mounted to each housing. The part number is explained as follows:
Legacy Part Number - Lamp Power and Type - Housing F/#
Legacy Part Number | Lamp Power and Type | Research Housing F/# |
---|---|---|
66479- 66481- 66941- 66942- 66944- |
200H-200 W Mercury 500H-500 W Mercury 350H-350 W Mercury |
R07-0.7 R1-1 R15-1.5 R22-2.2 |
The following 200-500 W Mercury Research Lamp Sources are available. Each Lamp Source includes the lamp, socket adapter, housing, cable and power supply as indicated in the table below.
Model | Lamp | Socket Adapter | Housing | Lamp Housing Interconnection Cable | Power Supply |
---|---|---|---|---|---|
66479-200H-R22 | 6283NS | 66144 | 67001 | 70051 | OPS-A500 |
66479-500H-R22 | 6285 | 66162 | 67001 | 70051 | OPS-A500 |
66479-350H-R22 | 6286 | 66161 | 67001 | 70051 | OPS-A500 |
66481-200H-R1 | 6283NS | 66144 | 67005 | 70051 | OPS-A500 |
66481-500H-R1 | 6285 | 66162 | 67005 | 70051 | OPS-A500 |
66481-350H-R1 | 6286 | 66161 | 67005 | 70051 | OPS-A500 |
66941-200H-R15 | 6283NS | 66144 | 66901 | 70051 | OPS-A500 |
66941-500H-R15 | 6285 | 66162 | 66901 | 70051 | OPS-A500 |
66941-350H-R15 | 6286 | 66161 | 66901 | 70051 | OPS-A500 |
66942-200H-R1 | 6283NS | 66144 | 66902 | 70051 | OPS-A500 |
66942-500H-R1 | 6285 | 66162 | 66902 | 70051 | OPS-A500 |
66942-350H-R1 | 6286 | 66161 | 66902 | 70051 | OPS-A500 |
66944-200H-R07 | 6283NS | 66144 | 66905 | 70051 | OPS-A500 |
66944-500H-R07 | 6285 | 66162 | 66905 | 70051 | OPS-A500 |
66944-350H-R07 | 6286 | 66161 | 66905 | 70051 | OPS-A500 |
Mercury lamps are excellent sources of high intensity DUV-VIS spectral lines; they are widely used as excitation sources. The systems described here run our 200, 350 and 500 W Hg lamps. You can interchange between lamps by simply changing socket adapters in the lamp housing. These sources consist of:
• Oriel Research Arc Lamp Housings with a condenser and a built-in ignitor as indicated per Model number in the table above
• OPS-A500 Power Supply
• Hg DC arc lamp as specified per Model number in the table above
• 70051 Lamp Housing Interconnection cable
The 67001 , 67005 , 66901 , 66902 , and 66905 can properly house and operate any 50-500 W DC arc lamp. If a light source from the above table is purchased, other DC Hg arc lamps can be used simply by changing the socket adapter and lamp inside the lamp housing. The appropriate socket adapter for each lamp is shown in the table below:
Mercury Arc Lamp | Lamp Wattage | Effective Arc Size (mm x mm) | Socket Adapter |
---|---|---|---|
6283NS | 200 | 0.6 x 2.2 | 66144 |
6286 | 350 | 0.8 x 2.7 | 66161 |
6285 | 500 | 1.1 x 4.1 | 66162 |
Fig. 1 Spectral irradiance of 200 W, 350 W, and 500 W Hg Lamps
The housing provides a temperature controlled, stable environment for the lamp, and protects personnel from the harmful UV radiation emitted by the lamp. A number of safety features are incorporated into the housing to prevent accidental exposure and lamp overheating. It also houses the ignitor and collimating lens assembly. A socket adapter holds the lamp, vertically, in the center of the lamp housing. To use another suitable lamp with the existing lamp housing, a different socket adapter must be used. External adjustment knobs allow for alignment of the lamp. A reflector mounted behind the lamp collects the lamp\'s back radiation and redirects it to the condenser, maximizing light output.
Various lamp housings are available for the 200-500 W Hg Research Arc Lamp Sources. Each lamp housing has a unique condensor lens assembly mounted to it. The optical characteristics per each lamp housing below should be considered when selecting a light source.
The new asphere condensers are corrected optics. The design corrects spherical aberration and lateral chromatic aberration with minimized longitudinal chromatic aberrations.
Series | Included Lamp Housing | Condenser Type | Output Beam | Output Beam Size | Lens Multiplication Factor* | Transmittance Range of Lens Material | Size Series |
---|---|---|---|---|---|---|---|
66479 | 67001 | F/2.2, fused silica asphere | Collimated | 1.3 | 0.05 | 200 - 2500 nm | 1.5 inch |
66481 | 67005 | F/1, fused silica asphere | Collimated | 1.3 | 0.11 | 200 - 2500 | 1.5 inch |
66941 | 66901 | F/1.5, single element fused silica | Collimated | 1.3 | 0.06 | 200 - 2500 | 1.5 inch |
66492 | 66902 | F/1, two element fused silica | Collimated | 1.3 | 0.11 | 200 - 2500 | 1.5 inch |
66944 | 66905 | F/0.7, four element fused silica Aspherab® | Collimated | 2.7 | 0.20 | 200 - 2500 | 3 inch |
The OPS-A500 power supply is dedicated to 200-500 W DC arc lamps. It is rugged, reliable and highly regulated. It operates any of the specified lamps under extremely tight power or current control. In addition to superior performance, this supply has a number of features to facilitate source operation. External control of the OPS-A500 can be done via USB or RS 232 interface.
Oriel lamp housings have adjustable height instrument feet. You can remove these and hard mount the housing to inch or metric optical tables and baseplates. The optical axis is 4.0 inches (102 mm) above the table. To mount a housing to a bench or rail, order the Carrier Mounting Kit. The kit includes a clamping carrier.
These sources emit dangerous levels of UV radiation and ozone. If you do not need output below ~260 nm, choose an ozone free lamp. If this is not an option, vent the ozone to the outside or use our Ozone Eater™ Ozone Converter. To protect yourself from the dangerous UV, wear Ultraviolet Safety Equipment like protective clothing, eyewear and gloves.