新势力光电供应压力传感器,特点:能效高、稳定性好、准确度高、适合恶劣环境。该系列压力传感器应用:工业生产、环境保护、测量、医学领域。
Model | HDU | HMU | |
Pressure ranges | 100 mbar to 5 bar | 100 mbar to 10 bar | |
1 to 70 psi | 1 to 70 psi | ||
Pressure type | Absolute, Gage, Differential | Absolute, Gage, Differential | |
Output signal | 100mV (FSO) | 100mV (FSO) | |
Thermal effects | Offset | ±0.02 %FSS/°C | ±0.02% FSS/°C |
Span | -0.2% FSS/°C | -0.2% FSS/°C | |
Bridge impedance | 0.26 %/°C | 0.26 %/°C | |
Temp. range operating | -40-85°C | -40-85°C | |
Dimensions without connections | 12×15×7mm³ | 10×13×6mm³ | |
Features |
Analogue sensor with |
Analogue sensor with | |
Cost-effective basic pressure sensor | Cost-effective basic pressure sensor | ||
Increased media compatibility |
Model | HCL | HDO | HRO |
Pressure ranges | 5 to 75 mbar | 10 mbar to 5 bar | 10 mbar to 10 bar |
2 to 30 inH2 | 4 inH2O to 70 psi | 4 inH2O to 150 psi | |
Pressure type | Gage, Differential | Absolute, Gage, Differential | Gage, Differential |
Output signal | 20mV (FSO) | 90mV (FSO) | 90mV (FSO) |
Accuracy, non-linearity | ±0.05 %FSO | ±0.1 %FSO (P-grade) | ±0.25 %FSS |
±0.2 %FSO (H-grade) | |||
Temp. range compensated | 0-70°C | 0-50°C | 0-70°C |
Temp. range operating | -25-85°C | -40-85°C | -25-85°C |
Dimensions without connections | 13×16×7mm³ | 12×15×7mm³ | 29×18×11mm³ |
Features | Analogue sensor with nearly unlimited resolution |
Analogue sensor with |
Analogue sensor with |
For very low pressures | Different accuracy classes available | Different accuracy classes available | |
Excellent offset stability | |||
Virtually no position sensitivity |
Model | HCLA | HCE | HDI |
Pressure ranges | 2.5 to 75 mbar | 10 mbar to 5 bar | 10 mbar to 5 bar |
1 to 30 inH2O | 4 inH2O to 70 psi | 4 inH2O to 70 psi | |
Pressure type | Gage, Differential | Absolute, Gage, Differential | Absolute, Gage, Differential |
Output signal | 0.25-4.25 V, I²C bus | 0.25-4.25 V, SPI bus | 0.5-4.5 V, I²C bus |
Accuracy, non-linearity | ±0.05 %FSS | ±0.1 %FSS | ±0.1 %FSS |
Accuracy, total accuracy | N.A. | ±0.5 %FSS | ±0.5 %FSS (P-grade) |
±1.5 %FSS (H-grade) | |||
Temp. range operating | -25-85°C | -25-85°C | -20-85 °C |
Dimensions without connections | 13×16×7mm³ | 13×16×7mm³ | 12×15×7mm³ |
Features | Digital signal conditioning | Digital signal conditioning | Digital signal conditioning |
For very low pressures | Very high total accuracy | Very high total accuracy | |
Excellent offset stability and virtually no position sensitivity | SPI bus interface and analogue output \\at the same time |
I²C bus interface and analogue output | |
I²C bus interface and analogue output | Different accuracy classes available |
Model | LBA | LDE |
Pressure ranges | 25 to 500 Pa | 25 to 500 Pa |
0.1 to 2 inH2O | 0.1 to 2 inH2O | |
Pressure type | Gage, Differential | Gage, Differential |
Output signal | 0.5-4.5 V | 0.5-4.5 V, SPI bus |
Offset stability | 0.3 % p.a. | 0.1 % p.a. |
Accuracy, total accuracy | ±1.5 %FSS | ±1.5 %FSS |
Dimensions without connections | 13×18×8mm³ | 13×18×8mm³ |
Features | Unmatched sensitivity and resolution | Unmatched offset stability, linearity, sensitivity and resolution |
Analogue signal conditioning | Digital signal conditioning with SPI bus interface and analogue output at the same time | |
Micro-flow channel integrated |
Micro-flow channel integrated | |
High immunity to dust, humidity and long tubing | High immunity to dust, humidity and long tubing | |
Miniature housing | Miniature housing |
Model | HMA | HMI | HME |
Pressure ranges | 100 mbar to 10 bar | 100 mbar to 10 bar | 101 mbar to 10 bar |
1 to 150 psi | 1 to 150 psi | 1 to 150 psi | |
Pressure type | Gage, Differential | Gage, Differential | Gage, Differential |
Output signal | 0.5-4.5 V | I²C bus | SPI bus |
Accuracy, non-linearity | ±0.25 %FSS | ±0.25 %FSS | ±0.25 %FSS |
Accuracy, total accuracy | ±1.5 %FSS | ±1.5 %FSS | ±1.5 %FSS |
Temp. range compensated | -20-85°C | -20-85°C | -20-85°C |
Dimensions without connections | 10×13×6mm³ | 10×13×6mm³ | 10×13×6mm³ |
Features | Increased media compatibility for gases and liquids | Increased media compatibility for gases and liquids | Increased media compatibility for gases and liquids |
Digital signal conditioning | Digital signal conditioning | Digital signal conditioning | |
Analogue output signal | I²C bus interface | SPI bus interface | |
Very small housings | Very small housings | Very small housings |
Model | SSO | SSI | KMA |
Pressure ranges | 200 mbar to 35 bar | 200 mbar to 35 bar | 500 mbar to 100 bar |
3 to 500 ps | 3 to 500 psi | 7 to 1500 psi | |
Pressure type | Absolute, Gage | Absolute, Gage | Gage |
Output signal | 100mV (FSO) | 0.5-4.5V, I²C bus | 0.5-4.5V |
Accuracy, non-linearity | ±0.1 %FSS | ±0.1 %FSS | ±0.4 %FSO |
Accuracy, total accuracy | ±1.5 %FSS | ±1.5 %FSS | ±1.5 %FSS |
Temp. range compensated | 0-50°C | -20-85°C | 0-85°C |
Temp. range operating | -40-125°C | -40-120°C | -20-85°C |
Dimensions without connections | Φ19mm | Φ19mm | Φ22×27mm |
Features | High media compatibility | High media compatibility | High media compatibility |
Fully welded stainless steel | Fully welded stainless steel construction | Ceramic pressure sensor element in stainless steel housing | |
Very high total accuracy | |||
I²C bus interface and analogue | |||
output at the same time | Digital signal conditioning |