Model | 200/75 | 400/140 | 600/210 | 1000/300 |
Wavelength (µm) | 9.2 - 10.8 | 9.2 - 10.8 | 9.2 - 10.8 | 9.2 – 10.8 |
Repetition rate (Hz) | 200 | 400 | 600 | 1000 |
Pulse energy - Multimode (J) | 0.35 | 0.35 | 0.35 | 0.3 |
Pulse energy - TEMoo (J) | 0.1 | 0.1 | 0.1 | 0.12 |
Average output power - Multimode (W) | 70 | 140 | 210 | 300 |
Average output power - TEMoo (W) | 20 | 40 | 60 | 120 |
Pulse width - FWHM of initial spike (ns) | 50 - 100 | 50 - 100 | 50 - 100 | 50 – 100 |
Output stability (1 sigma) | <4% | <4% | <4% | <4% |
Jitter (1 sigma) | <10ns | <10ns | <10ns | <10ns |
Beam height - Multimode (mm) | 15 | 15 | 15 | 12 |
Beam width - Multimode (mm) | 15 | 15 | 15 | 12 |
Beam Quality factor (M2) - Multimode | 3月6日 | 3月6日 | 3月6日 | 2 – 4 |
Beam waist - TEMoo (mm) | 5 | 5 | 5 | 4 |
Beam Quality factor (M2) - TEMoo | 1月2日 | 1月2日 | 1月2日 | 1 – 2 |
Operating pressure (atm) | 1 | 1 | 1 | 1 |
Dimensions (L x W x H) | 1.3m x 0.9m x 0.7m | 1.8m x 1.1m x 0.7m | 1.8m x 1.1m x 0.7m | 2.1m x 1.1m x 0.8m |
Weight - including transformer oil (kg) | 500 | 1300 | 1300 | 1800 |
Gas load lifetime for closed loop system | >100,000,000 pulses | |||
Electrical voltage | 208V, 380V 50/60Hz | |||
Phase | Three phase | |||
Pulse Circuit | Patented solid switch technology | |||
Pre-ionisation | Corona pre-ionised | |||
Cooling services Temperature stabilised, closed loop chilled water supply with temperature at 18C, with a heat removal capacity of: | ||||
5kW | 10kW | 15kW | 15kW | |
Optional extras | Manual wavelength tuner Side arm catalyst system | |||
Non-Destructive Testing (NDT) Isotope separation | ||||
Extreme Ultraviolet (EUV) generation systems THz imaging systems | ||||
Typical applications | Laser Marking systems |
THZ应用原理图