The Oriel SOL-UV-4 simulator incorporates a patent pending design certified to be compliant to FDA CFR Part 201.327, ISO 24444:2010(e) First Edition, and the International SPF Test Method (CTFASA/COLIPA/JCIA/CTFA: May 2006 for Spectral Match. With optional filter, it can deliver JCIA UVA compliant output. Validation is conducted by an independent, certified third party laboratory. Non-Uniformity of Irradiance is <5% over the entire sampling area. Output power can be varied from 10-100% of the maximum available solar constant for that model with a unique integrated attenuating device. The Oriel Sol UV simulators uses a black non-reflective finish to minimize stray light. Safety interlocks prevent inadvertent exposure to UV light. The Oriel Sol-UV simulators rugged design is backed by the Newport Corporation's world wide organization.
灯类型
Xenon
灯功率
1000 W
输出光束尺寸
101.6 x 101.6 mm
光束均匀性
≤5%
光束发散角(半角)
<±4 °
典型输出功率
6 Solar Constants
光谱匹配等级
FDA CFR Part 201.327, ISO 24444:2010(e), Intl SPF Test Method (CTFASA/COLIPA/JCIA/CTFA: May 2006
时间不稳定性等级
< 2% Over 24 hrs
均匀性等级
<5% non-uniformity
工作距离
4.0 ±0.5 in.
线性调整率
1E-4
电源要求
95-264 VAC/15A/47-63 Hz
Oriel SOL-UV-4模拟器结合了一项正在申请专利的设计,该设计符合FDA CFR Part 201.327, ISO 24444:2010(e)第一版,以及国际SPF测试方法(CTFASA/COLIPA/JCIA/CTFA: 2006年5月光谱匹配。通过可选的过滤器,它可以提供符合JCIA UVA的输出。验证由独立的、经过认证的第三方实验室进行。整个取样区域的辐照度不均匀度<5%。通过一个独特的集成衰减装置,该模型的输出功率可以从最大可用太阳常数的10-100%变化。Oriel Sol UV simulators使用黑色非反光光洁度来最小化杂散光。安全联锁防止意外暴露在紫外线下。Oriel Sol-UV模拟器坚固耐用的设计是由新港公司的全球组织支持的。