features HV pulse amplitude doubling layout and easy integration with HV powewr supply, PCD-UHV series Pockels cell drivers are excellent solution for OEM applications
Download datasheet (601.85 KB)
HV pulse amplitude up to 5.6 kV
HV repetition rate up to 10 kHz
HV pulse duration down to 15 ns
HV pulse amplitude doubling layout
Easy integration with HV power supply
Switchable one/two trigger pulses control mode
Specifications
Operation regime | 4.2 kV mode | 5.6 kV mode |
High voltage (HV) pulse amplitude to cell | 4.2 kV | 5.6 kV |
Output polarity | bipolar | |
HV pulse rise time, typical | 7 ns | 8 ns |
HV pulse fall time, typical | 7 ns | 8 ns |
HV pulse duration | 30-3000 ns | |
Maximal HV pulse repetition rate | 10 kHz | 5 khz |
External triggering pulse amplitude requirement | 3.5-5 V (50 Ω load) | |
External triggering pulse rise & fall time | < 5 ns | |
HV pulse delay | 30 ns | |
External powering requirements: | ||
HV power supply* | ≤ 2.1 kV, 5 W | ≤ 2.8 kV, 5 W |
low voltage DC supply, switchable | 14-25 V, 150 mA or 12 V, 220 mA (0.5 A inrush current) | |
Dimensions ( L x W x H) | ||
driver board | 135 x 65 x 25 mm | |
driver board mounted with HV05Wm power supply | 135 x 65 x 55 mm |
* Typical voltage control limits for HV05Wm are 1.8 to 2.8 kV. Other limits are available on your request.
Specifications are subject to changes without advance notice